Sec. 118-188. Location and connection requirements.

(a) Minimum size for any building sewer shall be four inches nominal diameter.

(b) A separate and independent building sewer shall be provided for every building, except where one building stands at the rear of another on an interior lot and no private sewer is available or can be constructed to the rear building through an adjoining alley, court, yard or driveway. Under such circumstances the building sewer from the front building may be extended to the rear building and the whole considered as one building sewer.

(c) No more than one dwelling unit may be served by the same building sewer except as follows: Where more than one dwelling unit is situated on the same lot or tract, as defined by the city subdivision rules and regulations, multiple units may be served by the same building sewer, provided that no more than four dwelling units are served by a four-inch line. Approval for installations serving more than one dwelling unit per individual building sewer will be at the discretion of the director, but each building sewer must be under the maintenance responsibility of only one ownership. Multiple dwelling units cannot be served by the same building sewer if the tract or lot can, in the opinion of the wastewater department, possibly be subdivided in the future.

(d) Where building sewers must be installed outside of the lot or tract on which the facility served is located, installation must be in the public right-of-way or in valid easements.

(Code 1973, § 33-97)