Sec. 66-44. Service buildings.
(a) Every mobile home park that accommodates dependent mobile homes shall be provided with at least one service building adequately equipped with flush-type toilet fixtures of a type approved by the state board of health, and other sanitary facilities as required in this article. No service building shall contain less than one toilet for females, one toilet for males, one lavatory and shower.
(b) All sanitary facilities required to be provided by this section shall be located in a service building.
(c) Every mobile home park that accommodates dependent mobile homes shall provide not less than the following facilities:
(1) For not more than ten dependent mobile homes: two water closets, one lavatory and one shower for females; one water closet, one urinal, one lavatory and one shower for males.
(2) For more than ten dependent mobile homes, the following additional fixtures shall be provided: one lavatory and one shower for each sex for every additional ten dependent mobile homes or fraction thereof; one water closet for females for every additional ten dependent mobile homes or fraction thereof; one water closet for males for every additional 15 dependent mobile homes or fraction thereof; provided, that urinals may be substituted for not more than one-third of the additional water closets required under this subsection.
(d) Dependent mobile home spaces shall not be more than 200 feet from a service building.
(e) Toilet and bathing facilities for female persons must be in a separate room from the room housing such facilities for male persons.
(f) Service buildings shall:
(1) Be located 15 feet or more from any mobile home space and where dependent mobile homes are accommodated not more than 200 feet from a dependent mobile home space.
(2) Be of permanent construction and be adequately lighted at all times.
(3) Be of moisture-resistant material, to permit frequent washing and cleaning.
(4) Have adequate heating facilities to maintain a temperature of 70 degrees Fahrenheit during cold weather, and to supply adequate hot water during time of peak loads.
(5) Have all rooms well ventilated, with all openings effectively screened.
(6) Provide separate compartments with adequate locking devices for each shower and water closet and a sound-resistant wall to separate male and female toilet facilities.
(g) If provided, laundry facilities shall be provided in the ratio of one laundry unit to every 30 mobile home spaces and shall be in a separate soundproof room of a service building or in a separate building.
(Code 1973, § 20-9)